4/30/2019

Arista optics with DOM support

DOM: 
  • Digital Optical Monitoring. 
  • Per industry standard - SFF-8742, and it gives end users the ability to monitor real-time parameters of SFP, such as in/output power, temperature, laser current and supply voltage
  • 2 Arista optical parts don't support full DOM:
    • 40G AOC doesn't support Tx Power
    • 10G AOC doesn't support DOM
  • EOS CLIs:
    • show int eth22/1 transceiver [detail]
  • https://www.cisco.com/c/en/us/products/collateral/interfaces-modules/transceiver-modules/data_sheet_c78-455693.html


upp106#show inv | grep SWDM

  22   Arista Networks  QSFP-100G-SWDM4  ATH173200003     20

upp106#show int eth 22/1 transceiver
If device is externally calibrated, only calibrated values are printed.
N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).
                               Bias      Optical   Optical
          Temp       Voltage   Current   Tx Power  Rx Power
Port      (Celsius)  (Volts)   (mA)      (dBm)     (dBm)     Last Update
-----     ---------  --------  --------  --------  --------  -------------------
Et22/1     33.00      3.30      7.69     1.32      0.44      0:00:01 ago


upp106#show int eth 22/1 transceiver de
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
                         High Alarm  High Warn   Low Alarm   Low Warn
           Temperature   Threshold   Threshold   Threshold   Threshold
Port       (Celsius)     (Celsius)   (Celsius)   (Celsius)   (Celsius)
-------    ------------  ----------  ----------  ----------  ----------
Et22/1     33.00         75.00       70.00       -5.00       0.00
                         High Alarm  High Warn   Low Alarm   Low Warn
           Voltage       Threshold   Threshold   Threshold   Threshold
Port       (Volts)       (Volts)     (Volts)     (Volts)     (Volts)
-------    ------------  ----------  ----------  ----------  ----------
Et22/1     3.30          3.60        3.47        2.97        3.10
                         High Alarm  High Warn   Low Alarm   Low Warn
           Current       Threshold   Threshold   Threshold   Threshold
Port       (mA)          (mA)        (mA)        (mA)        (mA)
-------    ------------  ----------  ----------  ----------  ----------
Et22/1     7.71          11.00       10.00       2.00        3.00
                         High Alarm  High Warn   Low Alarm   Low Warn
           Tx Power      Threshold   Threshold   Threshold   Threshold
Port       (dBm)         (dBm)       (dBm)       (dBm)       (dBm)
-------    ------------  ----------  ----------  ----------  ----------
Et22/1     1.33          6.00        5.00        -7.00       -6.00
                         High Alarm  High Warn   Low Alarm   Low Warn
           Rx Power      Threshold   Threshold   Threshold   Threshold
Port       (dBm)         (dBm)       (dBm)       (dBm)       (dBm)
-------    ------------  ----------  ----------  ----------  ----------
Et22/1     0.44          5.50        4.50        -16.00      -13.00

bn303.jhm.mlagA.profB.WORKING.17:56:54#sh int status  | grep 9/1/1
Et9/1/1        eth.mlag1601::2x25g::upp223_et1/1_et17/1<-->bn302|303_et9/1/1                 connected    in Po1601 full   25G    100GBASE-AR4

bn303.jhm.mlagA.profB.WORKING.17:56:39#sh int e9/1/1 transceiver
If device is externally calibrated, only calibrated values are printed.
N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).
                               Bias      Optical   Optical
          Temp       Voltage   Current   Tx Power  Rx Power
Port      (Celsius)  (Volts)   (mA)      (dBm)     (dBm)     Last Update
-----     ---------  --------  --------  --------  --------  -------------------
Et9/1/1    31.11      3.23      7.08     0.36      -2.36     0:00:03 ago
bn303.jhm.mlagA.profB.WORKING.17:56:46#sh int e9/1/1 transceiver detail
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
                         High Alarm  High Warn   Low Alarm   Low Warn
           Temperature   Threshold   Threshold   Threshold   Threshold
Port       (Celsius)     (Celsius)   (Celsius)   (Celsius)   (Celsius)
-------    ------------  ----------  ----------  ----------  ----------
Et9/1/1    31.53         80.00       75.00       -10.00      -5.00
                         High Alarm  High Warn   Low Alarm   Low Warn
           Voltage       Threshold   Threshold   Threshold   Threshold
Port       (Volts)       (Volts)     (Volts)     (Volts)     (Volts)
-------    ------------  ----------  ----------  ----------  ----------
Et9/1/1    3.23          3.63        3.46        2.97        3.14
                         High Alarm  High Warn   Low Alarm   Low Warn
           Current       Threshold   Threshold   Threshold   Threshold
Port       (mA)          (mA)        (mA)        (mA)        (mA)
-------    ------------  ----------  ----------  ----------  ----------
Et9/1/1    7.08          12.00       10.00       3.00        4.50
                         High Alarm  High Warn   Low Alarm   Low Warn
           Tx Power      Threshold   Threshold   Threshold   Threshold
Port       (dBm)         (dBm)       (dBm)       (dBm)       (dBm)
-------    ------------  ----------  ----------  ----------  ----------
Et9/1/1    0.36          5.40        2.40        -11.40      -8.40
                         High Alarm  High Warn   Low Alarm   Low Warn
           Rx Power      Threshold   Threshold   Threshold   Threshold
Port       (dBm)         (dBm)       (dBm)       (dBm)       (dBm)
-------    ------------  ----------  ----------  ----------  ----------
Et9/1/1    -2.39         5.40        2.40        -13.30      -10.30